I. The history of “TECOBAR”.
TAIAN-ECOBAR TECHNOLOGY (TET) was established in 1999 , and began locally producing the cast-resin insulated busway which was invested by an European manufacturer. With continuous concentration and dedication from our team, we are honor to launch a new brand “TECOBAR” into market since 2012. Enhanced electrical and mechanical strength with extraordinary fire retardant and waterproof property and maintenance free, TECOBAR’s highest quality and safety standard has achieved world leading class. TECOBAR aims to bring a clean environment and reliable power for our future. Therefore, continuous innovation and enthusiasm motivates TET to refine TECOBAR to provide a better solution.
II. Medium Voltage Busaway “TECOBAR” .
- Medium Voltage cast – resin Busway ( MV BUSWAY ).
- Medium Voltage Cast-Resin Non Segregated Phase Insulated Sandwich Busway System.Medium Voltage Busway Manufacturer.As a Medium Voltage Busway Supplier for more than 15 years, tecobar been specializing in providing Busway and Busduct.tecobar professional manufacturer of Medium Voltage Cast-Resin Insulated Busway.
- TECOBAR Medium Voltage Cast-Resin Insulated Busway is developed for power systems between 3.6kV~ 24kV.
III. Excellence
IV. Electrical characteri stics of Medium Voltage Busway.
3.1 Straight elements, Elbow elements, T-elements and Terminal elements, etc.
4.1 Altitude: below 1000m, indoor or outdoor site.
4.2 Ambient temperature: -45℃ ~ 65℃
4.3 Ambient humidity: 0% ~ 100%
5.1 Rated Voltage:
5.2 Frequency Hz: 50/60
5.3 System Type: 3 phase 3 wire.
5.4 Conductor Material : Copper (Purity : 99.9% Conductivity : Above 98% IACS)
and Aluminum.
According to standards : JIS H3140 , DIN 1787, DIN 1759, DIN 40500.
5.5 Electrical characteristics of each TECOBAR element:
Partial discharge : ◎ Partial discharge coulomb value less than 20pC.
Protection degree : ◎ In accordance with IEC 60529 IP68.
Mechanical impacts : ◎ In accordance with IEC 60068-2-75 IK10.
Insulation capabilities : ◎ Max 50kV/1min. (PE Type).
Tempreature rise limit : ◎ At average ambient temperature of 35℃ with daily peak 40℃
temperature rise of conductor ≦50K.
V. Why “ TECOBAR “ ?
- Cast-Resin Busway System :
- Cast-Resin (Junction Casted) :
- Certificates :
- Fireproof Behavior : Complied to the standard IEC 60331: 950℃, 3hrs. non-combustion-supporting and self-extinguishing.
- Protection level : IP classification (IEC 60529).
Level 6 :100% Dust proof.
Level 8:Immerse in water>1M for more than 1 HR.
- Mechanical impact:
- Seismic restraint :
Earthquake protection at 0.8G in tri-axial = Magnitude >7 passed.
- Explosion Proof : IEC 60079 certified with Ex mb II Gb.
- Compact dimension :
Whether office building, exhibition hall, data center, workshop, hospital or wind turbine, whether for the food industry, oil and gas, automotive industry, the chemical industry or manufacturing: busway trunking systems are used everywhere where a reliable, safe, and economical power distribution system must be ensured.
Check out some of the projects we have done: HERE!
Busway Documents: HERE!
For further information, please CONTACT us!